ASTM E1646 PDF

ASTM International E Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference. ASTM E(). Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure. ASTM E is the standard test method for water penetration of exterior metal roof panels by uniform static air pressure difference. The ASTM E test.

Author: Tygojora Kazilkis
Country: Georgia
Language: English (Spanish)
Genre: Life
Published (Last): 26 November 2011
Pages: 126
PDF File Size: 9.62 Mb
ePub File Size: 11.43 Mb
ISBN: 511-4-71120-993-7
Downloads: 11877
Price: Free* [*Free Regsitration Required]
Uploader: Kajijas

Referenced Documents ashm separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. SITC has utilized this test method to assist our clients with their quality assurance testing of metal panel roof systems. The preload test pressure differences positive and negative are to be specified.

Link e11646 Active This link will always route to the current Active version of the standard. This test method shall not, by itself, be relied upon to form conclusions about overall water penetration through metal roofs. The positive test pressure shall be greater than or equal to 15 pounds per square foot. A roof contains many details.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, including large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

  MANUAL DE SOLDADURA CON OXIACETILENO PDF

In service, the performance also depends on the rigidity of supporting construction, roof slope, and adtm the resistance of components to deterioration by various causes: It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Although prescribed modifications are outside the scope of this test method, an experienced testing engineer is able to use the principles presented in this test method and generate significant data by astmm specific details and measuring leakage.

Read more about what our customers have to say This test method is a specialized adaption of Test Method E Some designs are more sensitive than others to this upward moving water. This process is repeated for a total of three cycles. The calibrated spray racks shall deliver water uniformly against the roof surface at a minimum rate of five gallons per sstm foot per hour.

aetm

After applying the preload there is a two minute recovery period. The purpose of this test method is to conduct quality assurance water penetration testing of the roof including panel side laps and structural connections.

For that reason the slope of the roof plays a significant importance. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. In applying the asgm of tests by this method, note that the performance of a roof or its components, or both, may be a function of proper installation and adjustment.

  DESMONTANDO WIKILEAKS DANIEL ESTULIN PDF

ASTM E – Farabaugh Engineering and Testing

The slope of the roof is significant. Historical E16646 s – view previous versions of standard. A section of calibrated spray racks are set in place 12 inches above the specimen. These factors asmt be fully considered prior to specifying the test pressure difference. These notes and footnotes shall not be considered as requirements of the test method. It does not include leakage at openings or perimeter or any other details. Then the specimen is preloaded with a negative static air pressure differential for a minimum of 10 seconds.

For specific hazard statements, see 7. The test is conducted by attaching the chamber to the test specimen.

ASTM E1646

Practical considerations suggest that every combination of panel thickness, span, and design load need not be tested in order to substantiate product performance. Composite systems in which the source cannot be readily determined are outside the scope of this test method. This is a test procedure.

Prior to testing a positive static air pressure differential preload is applied. Pre-loading is a essential part of the testing procedure.