ISO 6507-1 PDF

hardness test —. Part 1: Test method. Matériaux métalliques — Essai de dureté Vickers —. Partie 1: Méthode d’essai. STANDARD. ISO. Fourth edition. ISO INTERNATIONAL. STANDARD. ISO. Third edition. Metallic materials — Vickers hardness test —. Part 1: Test method. Matériaux . I.S. EN ISO is the adopted Irish version of the European . The text of ISO has been approved by CEN as EN ISO.

Author: Akilkree Shakaktilar
Country: Montserrat
Language: English (Spanish)
Genre: Marketing
Published (Last): 1 September 2016
Pages: 295
PDF File Size: 20.87 Mb
ePub File Size: 17.67 Mb
ISBN: 650-2-20778-879-4
Downloads: 72928
Price: Free* [*Free Regsitration Required]
Uploader: Samuro

There is no general process of accurately converting Vickers hardness into other scales of hardness or into tensile strength. In general, as a result of the measurement, method 1 [Equation D. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s member body in the country of the requester.

Subscription pricing is determined by: The error b step 10 can be expected to be a systematic effect. The corresponding effect on the termination of the formation of an indentation can make alterations in the hardness value.

A record of these results should be maintained over a period of time, and used to measure reproducibility and monitor drift of the machine. For undated references, the latest edition of the referenced document including any amendments applies. Figure 1 — Principle of the test The Vickers hardness is proportional to the quotient obtained by dividing the test force by the sloping area of the indentation, which is assumed to be a right pyramid with a square base, and having at the vertex the same angle as the indenter.

If the document is revised or amended, you will be notified by email. The error is no longer in the calculation of the uncertainty but 6507-11 determined hardness values have to be corrected by b or Ucorr has to be increased by b. The finish of the surface shall permit accurate determination of the diagonal length of the indentation. It should be noted that for anisotropic materials, for example those which have been heavily cold-worked, there will be a difference between the lengths of the two diagonals of the indentation.

  AQIDA TAHAWIYYA ARABE PDF

The duration of the test force shall be 10 s to 15 s, except for tests 6507- materials 657-1 time-dependent properties would make this an unsuitable range. This part of ISO specifies the Vickers hardness test method, for the three different ranges of test force for metallic materials including hardmetals. The work of preparing International Standards is normally carried out through ISO technical committees. The procedure for the determination of U is explained in Table D.

In downloading this file, parties accept therein the responsibility of not kso Adobe’s licensing policy.

Independent of the type of sources, for hardness there are two possibilities for the determination of the uncertainty. In this case, an estimate of type Isso standard uncertainty may be obtained from the statistical analysis of repeated indentations into the test piece. ISO consists of the following parts, under the general title Metallic materials — Vickers hardness test: The correction factors are tabulated in terms of the ratio of the mean diagonal d of the indentation to the diameter D of the cylinder.

Need more than one copy?

Please first log in with a verified email before subscribing to alerts. NOTE 1 A strict comparison of hardness values is only possible at identical test forces. There is no correction of the hardness values with respect to the error.

Add to Alert PDF. The procedure for the determination of Ucorr is explained in Table D. In GUM, it is recommended to use a correction to compensate for such systematic effects. Care should be taken, if standard uncertainties of type A and B are summarised, that the contributions are not counted twice see Clause 4 of GUM: If not, an indirect verification should be performed.

  AMARAKOSHA ENGLISH PDF

BS EN ISO 6507-1:2018

NOTE 1 For indentation diagonals less than 0, mm, the increase 65507-1 the uncertainty has to be considered.

No deformation shall be visible at the back of the test piece after the test. Proceed to Checkout Continue Shopping. It is important that the test piece lies firmly on the support so that displacement cannot occur during the test.

Verlag Berliner Union Stuttgart,pp NOTE 2 In general, decreasing the test force increases the scatter of results of the measurements. It may not always be possible to quantify all the identified contributions to the uncertainty. The chain starts iwo the international level using international definitions of the various hardness scales to carry out international intercomparisons.

BS EN ISO – Metallic materials. Vickers hardness test. Test method

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. We have no amendments or corrections for this standard. It is strongly recommended that this procedure be applied for a maximum of 6507- year after the successful passing of a direct verification.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. The specification for the product isk indicate limits for the differences between the lengths of the two diagonals.